ET Tube
Normal – 3- 5cms above the carina (head neutral position)
The position of the ETT is dependent on the position of the head. If the neck is flexed, the tip of the tube descends in the trachea.
If included in the film, the mandible can be used for assessment of whether the neck is in a neutral position. In a neutral position, the lower border of the mandible should be projected over C5/C6. When flexed, the mandible projects around T1 and in extension, over C3/C4.
The carina is usually projected over T5-T7 (it descends with increasing age).
The desired position of an ETT is 5 ± 2 cm above the carina, but markedly varies with neck position and rotation and hence, the inclusion of the mandible is a helpful indicator:
flexed: 3 cm (± 2 cm) above carina
neutral: 5 cm (± 2 cm) above carina
extended: 7 cm (± 2 cm) above carina
Venous Lines
Chest Venous Line
PICC line Courtesy Radiopedia
Tunneled Dialysis Catheter
Tunneled dialysis catheter Courtey Radiopedia
Tunneled dialysis catheter Courtey Radiopedia
Swan Ganz Line
No further than the right main stem bronchus. Should not extend beyond the proximal interlobar artery (within 2cms of the hilum)
Swan Ganz line
NG Tubes
Side hole of the NG tube must be 2-3 cms below the GE junction
Dobhoff tube
NG Tube needs Advancement
Good Positioning of the ET Tube but NG tube needs to be advanced CXR Ashley Davidoff MD thecommonvein.net
Good Positioning of the ET Tube but NG tube needs to be advanced CXR Ashley Davidoff MD thecommonvein.net
Chest Tubes
Apical for pneumothorax and basilar for pleural effusion
Chest Tube in Good Position with Side holes inside the pleural cavity and position reflection an intra-fissural location
Chest tube in good position for drainage of a right pleural effusion. Modwerate sized left pleural effusion Ashley Davidoff MD thecommonvein.net
Pacemakers
Dual Lead Pacemaker
Case courtesy of Dr Jeremy Jones, Radiopaedia.org, rID: 6411
Posteroanterior and lateral chest radiographs of a pacemaker with normally located leads in the right atrium (white arrow) and right ventricle (black arrowhead), respectively. Courtesy Stephanie C Torres-Ayala, Guido Santacana-Laffitte, and José Maldonado
Biventricular Leads and Defibrillators
Three leads can be seen in this example of a cardiac resynchronization device: a right atrial lead (solid white arrow), a right ventricular lead (dashed black arrow), and a coronary sinus lead teal arrow). The coronary sinus lead wraps around the outside of the left ventricle, enabling pacing of the left ventricle. Note that the right ventricular lead in this case has 2 thickened aspects that represent conduction coils and that the generator is larger than typical pacemaker generators, demonstrating that this device is both a pacemaker and a cardioverter-defibrillator, capable of delivering electrical shocks for dangerously fast abnormal ventricular rhythms (see separate knol on Implantable Cardioverter-Defibrillators (ICDs). Gregory Marcus, MD, MAS, FACC
CXR A-P Dual lead pacemaker with defibrillator, with one electrode in the right atrial appendage and the second in the right ventricle. The thickened portions on the leads reflect the defibrillator component. Ashley Davidoff MD thecommonvein.net
CXR Lateral Dual lead pacemaker with defibrillator, with one electrode in the right atrial appendage and the second in the right ventricle. The thickened portions on the leads reflect the defibrillator component. Ashley Davidoff MD thecommonvein.net
CT scan showing dual lead pacemaker with defibrillator, with one electrode in the right atrial appendage and the second heading to the right ventricle. Ashley Davidoff MD thecommonvein.net
CT scan showing dual lead pacemaker with defibrillator, with one electrode in the right ventricular septum. The thickened portions on the leads reflect the defibrillator component. Ashley Davidoff MD thecommonvein.net
External Defibrillator
CXR – Post Partum Cardiomyopathy 35-year-old female with a 8 year history of post- partum cardiomyopathy presents with of chest pain. Frontal CXR shows global cardiomegaly, blunting of the right costophrenic angle with a suggestion of a subsegmental infiltrate in the right costophrenic angle, and a region of linear atelectasis in the right mid lung field. A small loculated right effusion is present. An external defibrillator is noted. No definite CHF Ashley Davidoff MD TheCommonVein.net 258Lu 136164
CT – Post Partum Cardiomyopathy with Pulmonary Emboli to Right Lower Lobe 35-year-old female with an 8-year history of post- partum cardiomyopathy presents with a history of chest pain. CT of chest with contrast in an axial projection, at the level of the heart, shows an enlarged left ventricle. The right lower lobe segmental arteries show filling defects and absence of contrast compared to the left lower lobe arteries. An external defibrillator is present. Ashley Davidoff MD TheCommonVein.net 258Lu 136165
Leadless Pacemaker
Leadless Pacemaker Case courtesy of Hilary Bowman, Radiopaedia.org, rID: 85742
Leadless Pacemaker Case courtesy of Hilary Bowman, Radiopaedia.org, rID: 85742
Leadless Pacemaker Case courtesy of Hilary Bowman, Radiopaedia.org, rID: 85742
Loop recorder
CXR Pulmonary Hemorrhage Ground Glass Changes and Consolidation 75-year-old man on blood thinners s/p aortic valve replacement s/p trauma, presents with hemoptysis. He was afebrile and without an elevated white count A loop recorder is noted overlying the left upper chest. Ashley Davidoff MD TheCommonVein.net 165Lu 135849
Atrial Appendage Hardware
Watchman Device
Watchman Device Xray – Case courtesy of Dr Aneta Kecler-Pietrzyk, Radiopaedia.org, rID: 52875
AtriClip
AtriClip Resembles a hair pin Case courtesy of Dr Aneta Kecler-Pietrzyk, Radiopaedia.org, rID: 52156
Chart with Appropriate Positioning of Lines and Tubes on the CXR Courtesy Wellington ICU
Links and References
Jain S A pictorial essay: Radiology of lines and tubes in the intensive care unit Indian J Radiol Imaging. 2011 Jul-Sep; 21(3): 182–190.